Technical Specification
AA Series Air-Cooled Air Compressor(20HP ~ 200HP)
Model
AA220A AA230A AA240A AA350A AA360A AA675A AA6100A AA6125A AA8150A AA8175A AA8200A

F.A.D.

(m3/min)
7 kgf/c㎡,G 2.4 3.8 5.0 6.4 7.5 10.5 14.0 16.5 21.3 24.7 27.9
Discharge Temp.(℃) Ambient Temperature + 15 ℃
Transmission Type. Belt Transmission Coupling Transmission
 Capacity Control Stepless Capacity Control
 Lubricant Oil Volume (L) 13 13 13 20 20 48 53 53 70 105 105
 Highest Ambient Temp.(℃) 45 ℃

Rated Output(HP) 20 30 40 50 60 75 100 125 150 175 200
Voltage(V) 3 Φ, 220 / 380 / 440 / 3300
Frequency(Hz) 50 / 60
Type / Insulation Grade Open Drip-Prof Type or Totally Enclosed Fan Cooled Type (option) / B or F Class
Starting Type Y -△
Cooling Medium Air-Cooled
Fan Power(kW) 0.25 0.25 0.35 0.55 0.75 0.75 1.1 1.1 1.5 3.0
Cooling Volume-Air(m3/min) 50 57 85 112 135 135 224 224 270 650 650
  Safety Switch Safety Valve. High Disch. Temp. Sw. High Disch. Pressure Sw. Overload. Power Loss. Phase Reversal
  Maintenance Indication Air Filter. Oil Filter. Oil Fine Separator. Oil Change. Belt Change
  Micro Computer Controller(Chinese/English)

Digital Temp./Pressure Display Control. Auto Running/Stop Control. Timer Running/Stop Control, Master/Slaver Interlock Control,Extended Remote Control

  Air Outlet Size 1 1/4" 1 1/2" 2" 2" 1/2" 3"
  L * W * H (mm) 1020*1000*1700 1150*
1180*1790
1150*
1180*1890
2000*
1400*1700
2100*
1546*1700
2150*
1450*1700
2200*
1700*1900
2800*
1650*1900
2800*
1650*1900
  Net Weight(kgw) 680 800 880 1100 1170 1800 2000 2100 2850 3000 3200
 


The Standard models are based on the supply air pressure below 10 Kg/c㎡G(included);the optional models are based on the using pressure between 11 Kg/c㎡G ~ 16 Kg/c㎡G
  • It is supplied only to the industrial application of the compressed air, and it will cause the injury, disease or death of the human owning to breath those compressed air unsuitably before being processed safely.
  • The suction air volumn is based on 1 atm (absolutely).32℃ ambient temp. 80% R.H. AIR.
  • The Hanbell reserver the rights to change the specification and designs without notice.